Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments |
---|---|---|---|---|---|
ACI.02 | Environmental noise: Measurement of sound pressure levels. Determination of the average long-term exposure sound level. | NP ISO 1996-1:2021; NP ISO 1996-2:2021; NP ISO 1996-2:2021/Erratum1:2022; Internal Procedure ACI.02.IE.01 (version no. 10 of October 2022) | Environmental noise | ||
ACI.03 | Building acoustics: Measurement of airborne sound insulation between rooms and determination of the sound insulation index (except low-frequency sound insulation in rooms with a volume less than 25 m3) | ISO 16283-1:2014; ISO 16283-1:2014/Amd1:2017; ISO 717-1:2020 | Building elements | The standardised low frequency sound insolation is performed in compartments with a volume below 25m3 | |
ACI.04 | Building acoustics: Measurement of sound insulation of facades and facade elements and determination of the sound insulation index. Global loudspeaker method (except standardized low-frequency sound insulation in rooms with a volume less than 25 m3) | ISO 16283-3:2016; ISO 717-1:2020 | Building elements | Except standardised low frequency sound insolation in compartments with a volume less than 25m3 | |
ACI.05 | Building acoustics: Measurement of reverberation time. Interrupted noise method (Engineering Method) | ISO 3382-2:2008; ISO 3382-2:2008/Cor.1:2009 | |||
ACI.06 | Building acoustics: Measurement of impact sound insulation of floors and determination of the sound insulation index (except the standardized low-frequency sound insulation in rooms with a volume less than 25 m3) | ISO 16283-2:2020, ISO 717-2:2020 | Building elements | Except the standardized low frequency sound insulation in rooms with a volume less than 25m3 | |
ACI.07 | Building acoustics: Measurement of sound pressure level from service equipment in buildings. Determination of the sound level of particular noise | NP EN ISO 16032:2009; Note 4 of National Laboratory for Civil Engineering Document, 10 of July 2015 | |||
ACI.08 | Environmental noise: Measurement of sound pressure levels. Determination of the equivalent sound level | NP ISO 1996-1:2021; NP ISO 1996-2:2021; NP ISO 1996-2:2021/Erratum1:2022; Internal Procedure ACI.08.IE.01 (version no. 10 of October 2022) | |||
ACL.01 | Laboratory test: Measurement of airborne sound reduction index for Rw. Range: Rw ≤ 72 dB | ISO 10140-1:2021 (except annexes J and K); ISO 10140-2: 2021; ISO 10140-4:2021; ISO 717-1:2020 | Building elements | EN 1793-2:2018, EN 1793-3:1997 (only applicable to noise barriers intended for road traffic); EN 16272-2:2012, EN 16272-3-1:2012 (only applicable to noise barriers intended for railway) | |
ACL.12 | Estimate of airborne sound insulation index of windows, Rw | EN 14351-1:2006+A2:2016 (Annex B) | Windows | Calculation | |
ACL.15 | Laboratory test: Acoustic intensimetry | ||||
ACL.18 | Laboratory measurement of airborne sound transmission loss, TL | Test procedure adapted from standards ASTM E90-09; ASTM E2235-04, ASTM E413-22 and ASTM E1332-22 | Construction products | ||
CXL.01 | Determination of the air permeability of doors and windows | EN 1026:2016, EN 12207:2016 | Doors and windows | ||
CXL.02 | Determination of water tightness of doors and windows | EN 1027:2016, EN 12208:1999 | Doors and windows | ||
CXL.03 | Determination of the resistance to wind load of doors and windows | EN 12211:2016, EN 12210:2016 | Doors and windows | ||
CXL.04 | Determination of the resistance to racking | EN 14608:2004 | Windows |