Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments |
---|---|---|---|---|---|
ACL.16 | Laboratory test: Determination of sound power level of noise sources through the measurement fof the sound pressure levels - Precision method for semi-anechoic rooms | ISO 3745:2012; ISO 3745:2012/Amd1::2017 | Noise Sources | ||
ACL.17 | Laboratory test: Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (hemi-anechoic chamber) | ISO 3744:2010 | Noise of machinery and equipment | ||
ACL.17.02 | Determination of sound power levels of noise sources using sound pressure - Engineering Method | ISO 3744:2010 | Noise of machinery and equipment | ||
ACL.19 | Laboratory test: Determination of sound power level of noise using sound pressure - Survey method using an eveloping measurement surface over a reflecting plane (in a hemi-anechoic chamber) | ISO 3746:2010 | Noise of machinery and equipment | ||
ACL.19.02 | Determination of the sound power level of noise using sound pressure - Survey method using an eveloping measurement surface over a reflecting plane | ISO 3746:2010 | Noise of machinery and equipment | ||
EQP.06 | Determination of performance and energy consumption of compact air / water heat pumps with built-in water tank | EN 16147; Regulation (EU) No. 812/2013 of 18 February 2013 and Regulation (EU) No. 814/2013 of 2 August 2013 | Compact air / water heat pumps with built-in water tank | The test can be performed according to EN 16147:2011; EN 16147:2011/AC:2011 or EN 16147:2017; EN 16147:2017/AC:2017 (except section 7.11). | |
EQP.10 | Determination of useful storage volume and heat loss of hot water tanks | EN 12897:2006 (sections 6.2.2 and 6.2.7 and Annex B); Regulation (EU) No. 812/2013 of 18 February 2013 (point 2 of Annex II and Annex IX) | Reservatórios de água quente | ||
EQP.14 | Storage volume and heat loss determination of hot water tanks | EN 15332:2007 - ponto 5.4; Regulamento Delegado (UE) Nº 812/2013 | Reservatórios de água quente | ||
EQP.15 | Electrical Safety - Heat pumps for DHW | EN 60335-1, IEC 60335-1 (except section 29.2 and Annex N); EN 60335-2-40, IEC 60335-2-40 | Heat pumps | EN 60335-1:2012, EN 60335-1:2012/AC:2014, EN 60335-1:2012/A11:2014, EN 60335-1:2012/A13:2017, EN 60335-1:2012/A1:2019, EN 60335-1:2012/A2:2019, EN 60335-1:2012/A14:2019, EN 60335-1:2012/A15:2021; IEC 60335-1:2010 (except section 29.2 and Annex N), IEC 60335-1:2010/A1:2013+COR1:2014, IEC 60335-1:2010/A2:2016+COR1:2016; EN 60335-2-40:2003, EN 60335-2-40:2003/A11:2004, EN 60335-2-40:2003/A12:2005, EN 60335-2-40:2003/A1:2006, EN 60335-2-40:2003/AC:2006, EN 60335-2-40:2003/A2:2009, EN 60335-2-40:2003/AC:2010, EN 60335-2-40:2003/A13:2012, EN 60335-2-40:2003/A13:2012/AC:2013; IEC 60335-2-40:2002+A1:2005, IEC 60335-2-40:2002/A2:2005 | |
EQP.17 | Determination of the sound power level of heat pumps for domestic hot water | EN 12102-2:2019 | Heat pump for domestic hot water |