Itecons has laboratory capacity to assist the industry in the development of water and environment heating equipment.
Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments |
---|---|---|---|---|---|
EQP.06 | Determination of performance and energy consumption of compact air / water heat pumps with built-in water tank | EN 16147; Regulation (EU) No. 812/2013 of 18 February 2013 and Regulation (EU) No. 814/2013 of 2 August 2013 | Compact air / water heat pumps with built-in water tank | The test can be performed according to EN 16147:2011; EN 16147:2011/AC:2011 or EN 16147:2017; EN 16147:2017/AC:2017 (except section 7.11). | |
EQP.10 | Determination of useful storage volume and heat loss of hot water tanks | EN 12897:2006 (sections 6.2.2 and 6.2.7 and Annex B); Regulation (EU) No. 812/2013 of 18 February 2013 (point 2 of Annex II and Annex IX) | Reservatórios de água quente | ||
EQP.11 | Performance acceptance test of hydraulic pump (fluid equated to water) | ||||
EQP.12 | Determination of flow in open channel | Internal Procedure EQP.12.IE.01 (version no. 4 of August 2021) | Free surface flowmeters | MCERTS: performance standards and test procedures for continuous water monitoring equipment - part 3 water flowmeters, Version 2.4, 02/2013 | |
EQP.13 | Electric safety - Electric pitchers | EN 60335-1, IEC 60335-1 (except section 29.2 and Annex N); EN 60335-2-15, IEC 60335-2-15 | Kettles / Jugs | EN 60335-1:2012, EN 60335-1:2012/AC:2014, EN 60335-1:2012/A11:2014, EN 60335-1:2012/A13:2017, EN 60335-1:2012/A1:2019, EN 60335-1:2012/A2:2019, EN 60335-1:2012/A14:2019, EN 60335-1:2012/A15:2021; IEC 60335-1:2010 (except section 29.2 and Annex N), IEC 60335-1:2010/A1:2013+COR1:2014, IEC 60335-1:2010/A2:2016+COR1:2016; EN 60335-2-15:2016, EN 60335-2-15:2016/A11:2018, EN 60335-2-15:2016/A1:2021, EN 60335-2-15:2016/A2:2021, EN 60335-2-15:2016/A12:2021; IEC 60335-2-15:2012, IEC 60335-2-15:2012/A1:2016, IEC 60335-2-15:2012/A2:2018. | |
EQP.14 | Storage volume and heat loss determination of hot water tanks | EN 15332:2007 - ponto 5.4; Regulamento Delegado (UE) Nº 812/2013 | Reservatórios de água quente | ||
EQP.15 | Electrical Safety - Heat pumps for DHW | EN 60335-1, IEC 60335-1 (except section 29.2 and Annex N); EN 60335-2-40, IEC 60335-2-40 | Heat pumps | EN 60335-1:2012, EN 60335-1:2012/AC:2014, EN 60335-1:2012/A11:2014, EN 60335-1:2012/A13:2017, EN 60335-1:2012/A1:2019, EN 60335-1:2012/A2:2019, EN 60335-1:2012/A14:2019, EN 60335-1:2012/A15:2021; IEC 60335-1:2010 (except section 29.2 and Annex N), IEC 60335-1:2010/A1:2013+COR1:2014, IEC 60335-1:2010/A2:2016+COR1:2016; EN 60335-2-40:2003, EN 60335-2-40:2003/A11:2004, EN 60335-2-40:2003/A12:2005, EN 60335-2-40:2003/A1:2006, EN 60335-2-40:2003/AC:2006, EN 60335-2-40:2003/A2:2009, EN 60335-2-40:2003/AC:2010, EN 60335-2-40:2003/A13:2012, EN 60335-2-40:2003/A13:2012/AC:2013; IEC 60335-2-40:2002+A1:2005, IEC 60335-2-40:2002/A2:2005 | |
EQP.17 | Determination of the sound power level of heat pumps for domestic hot water | EN 12102-2:2019 | Heat pump for domestic hot water | ||
EQP.18 | Requirements and test of wood stoves | EN 13240:2001, EN 13240:2001/A2:2004, EN 13240:2001/A2:2004/AC:2007 and EN 13240:2001/AC:2006 | Wood stoves | ||
EQP.19 | Requirements and test of stoves and fireplaces | EN 13229:2001+A1:2003+A2:2004+AC:2006+A2:2004/AC:2007 | Stoves, fireplaces | ||
QUI.204 | Photometer verification in pH determination | Equipment manual | Photometer | --- | |
QUI.205 | Photometer verification in iron determination | Equipment manual | Photometer | --- | |
QUI.206 | Photometer verification in manganese determination | Equipment manual | Photometer | --- | |
QUI.207 | Photometer verification in aluminium determination | Equipment manual | Photometer | --- | |
QUI.208 | Photometer verification in alkalinity determination | Equipment manual | Photometer | --- |