Energy performance, environmental impact and safety are increasingly more relevant when choosing construction material and equipment. Itecons has facilities to carry out tests catering to these concerns.
Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments |
---|---|---|---|---|---|
CXL.01 | Determination of the air permeability of doors and windows | EN 1026:2016, EN 12207:2016 | Doors and windows | ||
CXL.16 | Determination of the thermal transmittance of doors and windows by hot box method | EN ISO 12567-1:2010, EN ISO 12567-1:2010/AC:2010 | Doors and windows | Range: Doors and windows less than or equal to 2m x 2m | |
CXL.17 | Determination of the thermal transmittance of doors and windows | ISO 10077-1:2017, ISO 10077-2:2017 | Doors and windows | ||
CXL.21 | Determination of the air permeability of doors, windows and curtain walling | ASTM E283 / E283M | Doors, windows and curtain walling | ||
EQP.02 | Residential space heating appliance, fired by wood pellets with nominal heat output up to 50 kW | NP EN 14785:2008 (sections 4, 5 (except section 5.9), 6, 7, 8); fuel characterization tests according to Annex B of NP EN 16510-1: 2020 | Residential space heating appliance | ||
EQP.06 | Determination of performance and energy consumption of compact air / water heat pumps with built-in water tank | EN 16147; Regulation (EU) No. 812/2013 of 18 February 2013 and Regulation (EU) No. 814/2013 of 2 August 2013 | Compact air / water heat pumps with built-in water tank | The test can be performed according to EN 16147:2011; EN 16147:2011/AC:2011 or EN 16147:2017; EN 16147:2017/AC:2017 (except section 7.11). | |
EQP.10 | Determination of useful storage volume and heat loss of hot water tanks | EN 12897:2006 (sections 6.2.2 and 6.2.7 and Annex B); Regulation (EU) No. 812/2013 of 18 February 2013 (point 2 of Annex II and Annex IX) | Reservatórios de água quente | ||
EQP.11 | Performance acceptance test of hydraulic pump (fluid equated to water) | ||||
EQP.14 | Storage volume and heat loss determination of hot water tanks | EN 15332:2007 - ponto 5.4; Regulamento Delegado (UE) Nº 812/2013 | Reservatórios de água quente | ||
EQP.15 | Electrical Safety - Heat pumps for DHW | EN 60335-1, IEC 60335-1 (except section 29.2 and Annex N); EN 60335-2-40, IEC 60335-2-40 | Heat pumps | EN 60335-1:2012, EN 60335-1:2012/AC:2014, EN 60335-1:2012/A11:2014, EN 60335-1:2012/A13:2017, EN 60335-1:2012/A1:2019, EN 60335-1:2012/A2:2019, EN 60335-1:2012/A14:2019, EN 60335-1:2012/A15:2021; IEC 60335-1:2010 (except section 29.2 and Annex N), IEC 60335-1:2010/A1:2013+COR1:2014, IEC 60335-1:2010/A2:2016+COR1:2016; EN 60335-2-40:2003, EN 60335-2-40:2003/A11:2004, EN 60335-2-40:2003/A12:2005, EN 60335-2-40:2003/A1:2006, EN 60335-2-40:2003/AC:2006, EN 60335-2-40:2003/A2:2009, EN 60335-2-40:2003/AC:2010, EN 60335-2-40:2003/A13:2012, EN 60335-2-40:2003/A13:2012/AC:2013; IEC 60335-2-40:2002+A1:2005, IEC 60335-2-40:2002/A2:2005 | |
EQP.16 | Performance tests of residential solid fuel burning appliances | EN 16510-1:2018 | Residential solid fuel burning appliances | ||
EQP.17 | Determination of the sound power level of heat pumps for domestic hot water | EN 12102-2:2019 | Heat pump for domestic hot water | ||
ETI.01 | Determination of water absorption of ETICS - Capillarity test | EAD 040083-00-0404 of 2019 (section 2.2.5.1) | ETICS | ||
ETI.02 | Determination of water tightness of ETICS - Resistance to hygrothermal cycles | EAD 040083-00-0404 of 2019 (section 2.2.6) | ETICS | ||
ETI.03 | Determination of water tightness of ETICS - Resistance to freeze-thaw | EAD 040083-00-0404 of 2019 (section 2.2.7) | ETICS |